Model #: InfraStruXure InRow SC
InfraStruXure InRow SC by APC
The predictable solution for an unpredictable environment.
New technologies are increasing heat loads in today’s server rooms and wiring closets, which often lack adequate cooling. The APC InfraStruXure InRow SC is a self-contained cooling solution that maximizes availability within small IT rooms. This energy-efficient unit lowers operating costs by using variable speed fans, capacity modulation, and an in-row form factor. The InRow SC's plug-and-play design allows for rapid installation without the need for running refrigerant lines or providing remote heat exchangers. The predictive failure notification and high head pressure protection features, along with hot-swappable fans, improve the availability of IT equipment.
Information:

Buy Specifications

  • Easy to install - Self-contained design allows for fast installation without refrigerant lines or remote heat exchangers. Unit requires only power, condensate drain and an available return plenum to provide effective cooling.
  • In-Row architecture - Provides increased predictability of cooling performance.
  • Modular design - Modular design provides scalable solutions to add cooling as demand increases.

    Manageability
  • Real-Time Capacity Monitoring - Real-time display of current and available cooling.
  • Microprocessor controller - The system is controlled by a microprocessor, with an 80-character LCD backlit alphanumeric display, that provides communication and alarm indication.
  • Network manageable - View the user interface with a browser. Gives quick access from anywhere on the network.
  • InfraStruXure Manager compatible - Enables centralized management via the APC InfraStruXure® Manager.
  • Building Management System Integration - Send alarms and data points allowing you to manage critical building infrastructure from a single system.

    Availability
  • Ducted Condenser Air - Uses unconditioned air from plenum space to reject the heat rather than conditioned room air.
  • Built-In Condensate Pump - Factory installed pump collects and removes water from the air conditioner, ensuring continuous operation.
  • High Head Pressure Protection - Ensures the InRow SC remains operational even when the condenser inlet air is restricted or very hot.
  • Coil freeze protection - Hot gas bypass prevents evaporator coil from freezing during light load conditions.
  • Predictive failure notification - Maximizes system availability by providing early warning of required fan or filter replacement.
  • Automatic restart - In the event of a power failure the InRow SC will resume operation.

    Serviceability
  • Hot swappable fans - Allows system to remain operational if a fan replacement is required.
  • Washable filters - Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

    Total Cost of Ownership
  • Rack Inlet Temperature Control - Reduces the risk of hot spots at the rack level.
  • Variable speed fans - Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Green Refrigerant - Environmentally friendly refrigerant that can offer LEED points.