Rack Air Removal Unit SX

Model #: Rack Air Removal Unit SX
Rack Air Removal Unit SX by APC
The only manageable rack heat removal solution.
High-density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit SX captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance. With a unit-mounted LCD display users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit SX. This space-saving product mounts to the back of either the NetShelter SX or VX enclosure - requiring zero U space.
Information:

Buy Specifications

  • Network manageable - View the user interface with a browser. Gives quick access from anywhere on the network.
  • InfraStruXure Manager compatible - Enables centralized management via the APC InfraStruXure® Manager.
  • Temperature monitoring - Allows up to 3 remote sensors to monitor rack inlet temperature.
  • LCD display - Accessible without opening the door for easy operation. Allows user to locally monitor and control the unit.

    Availability
  • Fault-tolerant fan system - In event of a fan failure the remaining fans will speed up to compensate. Fans are N+1 redundant up to 1500 CFM of airflow.
  • Dual A-B power inputs - Draws power from the UPS for power protection with dual feeds for redundancy.
  • Ducted Exhaust System - Removes hot air from the data center to prevent re-circulation and eliminate air mixing.
  • Field replaceable components - Fans and electronics module can be readily replaced without uninstalling the unit.

    Adaptability
  • Adjustable mounting frame - The frame can mount on Netshelter SX or VX enclosures and extends to accommodate 42U, 47U or 48U rack heights.
  • Zero "U" Solution - Mounts to the rear of the rack, leaving valuable rack space for other equipment.

    Total Cost of Ownership
  • Easy to install - Innovative design allows for fast, easy installation by almost anybody.
  • Variable speed fans - Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Increased capacity - Higher rate of heat removal allows more equipment to be installed in each rack.