Network and Data Center Solutions
Power Management & StripsServer Technology3 Phase Power Distribution & Metering

Switched CDU CW-48VD/VY-3Ph

Model #: CW-48VD/VY-3Ph
Switched CDU CW-48VD/VY-3Ph by Server Technology
The Switched 48-VD/VY CDU combines remote configuration and management with power distribution, power monitoring and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Choose one power distribution unit for your high-density cabinets. Only our Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring. US Patent 7,043,542 (Patent Pending)

Request Info Features and Benefits

Sentry Switched CW-48VY CDU Specifications

Item #

Available Input
Voltages

Rated Amperage

Available Input Cord

Outlets

Dimensions

CW-48VD-L1520

3 Phase Delta, 208V
50/60Hz

20A

NEMA L15-20P
Cordset

(48) IEC 60320/C13

62.0" (L)
3.5" (W)
2.25” (D)

CW-48VD-L1530

3 Phase Delta, 208V
50/60Hz

30A

NEMA L15-30P
Cordset

(48) IEC 60320/C13

62.0" (L)
3.5" (W)
2.25” (D)

CW-48VY-L2120

3 Phase Wye, 208V
50/60Hz

20A

NEMA L21-20P
Cordset

(48) IEC 60320/C13

62.0" (L)
3.5" (W)
2.25” (D)

CW-48VY-L2130

3 Phase Wye, 208V
50/60Hz

30A

NEMA L21-30P
Cordset

(48) IEC 60320/C13

62.0" (L)
3.5" (W)
2.25” (D)

*European Model
Additional Specifications
Standards Power Cords
  > CTUVus – UL 60950-1-2003
  > CAN/CSA 22.2 No. 60950-1:2003
  > TUV_GS – EN60950-1:2001

Communications
  > 10/100 BaseT Ethernet
  > SSLv3/TLSv1
  > SNMPv2

Accessories
  > Temperature & Humidity Probe Option
   > EMTH-1-1 Temperature & Humidity Probe, 10’
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P (20A Twist-Lock) 10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17) 16/20A     Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
Branch Circuit Protection
> Compliant to UL 60950-1
 

24-character Outlet Receptacles Names

Use the firmware interface (Web or serial) to edit individual outlet receptacles. Identify each receptacle with the device's serial number, ip address, asset allocation #, department or any other method to individually name outlets.

Add a Second Tower

Connect an Expansion Module to any Smart or Switched CDU to control two power input circuits and 32 managed outlets (individual or groups) - our exclusive strategy for managing dual power-supply servers.

Firmware Flash Upgradeable

Access new firmware updates via FTP for new firmware features and code releases. An update to the firmware does not affect the status of the power outlets.

HTTP/HTTPs Web Configuration & Control

Use the Sentry Web interface to configure each unit, including network settings, outlet naming & grouping, SNMP traps for environmental & power thresholds and firmware updates. Also use the Web interface to control individual or group outlets and monitor key values, including amperage load(s), temperature/humidity and other environmental conditions. SSL security provides a secure HTTPs connection.

Integrate Environmental Monitoring

The EMCU - Environmental Monitor integrates easily with the Power Tower XL, or other Sentry Remote Power Manager. Locate the EMCU in the equipment cabinet with a PTXL, link it to the PTXL and view temperature, humidity, water sensing and dry contact closures from the same PTXL interface you use to manage and monitor the power.

Integrated Temp/Humidity Probes

Two (2) RJ-style connectors located on the face panel of the PDU's enclosure provide support for two (2) Integrated Temperature & Humidity Probes with ten-foot (10') cables provide real-time measurements in the data center cabinet.

LDAP

LDAP (Lightweight Directory Access Protocol) is a software protocol for enabling anyone to locate organizations, individuals, and other resources such as files and devices in a network, whether on the public Internet or on a corporate intranet. Sentry firmware code 5.3b and newer  includes support for LDAP v3 and is configurable to operate with any Directory Service. It has been tested with these Directory Services: Microsoft’s Active Directory, Novell’s eDirectory, OpenLDAP

Load Sense

Individual input current monitoring ("Load Sense") provides real-time power measurement of the load in amps on each power inlet, accessible via firmware interface.

Remote Power Control

Individual or group outlet remote power control to cycle power and reboot any selected server(s) or other network device(s).  Use TCP/IP (HTTP, HTTPS, SSH, Telnet, SNMP) or RS-232 to communicate with each Sentry and rectify locked-up network devices. Assign outlets to a group for control of dual-power supply servers and other gear with a single command.  Create an unlimited number of groups with any combination of outlets associated to each group. Reduce Mean Time to Repair (MTTR) of a failing server by controlling individual power outlet receptacles to reboot any selected server or other device.

RS-232 Control

Serial control via any device with a bi-directional serial port, including a PC, laptop, KVM switch, Console Port Access switch, or terminal server.

Secure Access - SSH or SSL Protection

Secure Shell (SSH), sometimes known as Secure Socket Shell, is a Unix-based command interface and protocol for securely getting access to a remote device.  Sentry supports SSHv2. Secure Sockets Layer (SSL) is a commonly-used protocol for managing the security of a message transmission on the Internet. SSL is an integral part of most Web browsers (clients) and Web servers.  Sentry supports SSLv3/TLSv1.

SNMP Management & Event Notification

The Sentry family of products supports the Simple Network Management Protocol (SNMP). This allows network management systems to use SNMP requests to retrieve information and control power for the individual outlets. The Sentry includes an SNMP v1 agent supporting standard MIB I and MIB II objects. A private enterprise MIB extension (Sentry3 MIB) is also supported to provide remote power control. SNMP traps can be generated for various events, including Input Current Load Thresholds (min & max), Temperature Thresholds (min & max), Humidity Thresholds (min & max), water indication, closed contacts (cabinet doors open/close), as well as notification of any time an outlet status is changed (on/off).

Zero U Enclosure

A vertical enclsoure that occupies Zero Vertical U of rack space in the equipment cabinet. It mounts on the back rails or in the cavitity space of the cabinet.